Description

@malte-storm

The noise parameter in the sinograms only increases the absorption, never decreases it, see image:
xdesign_noisecomparison_line

This introduces a statistical bias. I think the reason for this behaviour is that noise is added for the attenuation data and not for the measured data

def measure(self, phantom, noise=False):
    [...]
    if noise > 0:
        newdata += newdata * noise * np.random.poisson(1)
    self.record()
    return newdata

The way a "normal" tomography measurement works is by dividing (dark-current normalized) camera images: projection divided by flat-field. These images both have Poisson-distributed counting errors.
The variance variance of the Poisson distribution equals lambda:
VAR = sigma^2 =lambda
For a noise level equivalent to one standard deviation (i.e. sigma = noise ), this corresponds to a count rate of counts = noise^(-2)
I would suggest the noise application to be done in the following manner:

    if noise > 0:
        counts = noise**(-2)
        newdata = -numpy.log(numpy.random.poisson(counts * numpy.exp(-newdata)) / numpy.random.poisson(counts))

This approach creates a nice and uniform histogram of the noise around the expected value.
However, this approach would require that newdata is scaled reasonable, i.e. ideally newdata would be in [0, 3] and would support using "real world units".
It is obviously also more computational intensive than the old approach but considering the time required for computing all phantom intersections, I expect this to be negligible.

This is an example of how the histograms look like (500,000 random number pairs) with a transmission value of 0.25 (exp(-newdata) = 0.25):
xdesign_statistics

Activity

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

Type

No type

Projects

No projects

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions