Description
What happened?
when you add parameters to a S7 request, you have two ways to do it:
builder.addTagAddress( "name", "%DB69:68:STRING(20)" )builder.addTag( "name", S7Tag.of("%DB69:68:STRING(20)" )
however, in the second form we get an error, because the S7Tag.of() notation does not recognize the string-length parameter. It may be good enough when reading a string from PLC, but will make a mess when writing.
Looking into S7Tag.of() and addTagAddress() shows, that S7Tag.of() does not use the regexes which could handle the added "(20)" length parameter. addTagAddress() uses these regexes and can deal with this addresses.