Hi Richard !
Here are the results of my comparison of the calibration for cameras V1 and V2 with a non-stock lens.
- To get the right table you have to run the script with hflip = vflip = True for V2 and hflip = vflip = false for v1, then the table works in all four cases!
- The "openloop" script gives much better results than the script on the Bayer capture.
- It appears that the camera V1 requires very little calibration, there is no drift of colors but only a central circle less bright.
- Even with a careful calibration the V2 camera shows for some yellow-dominant images a yellow central circle. For my project the camera V1 seems a better choice.
Dominique
Below for V1 and V2
Unscaled and calibrated white image
An uncalibrated and calibrated image, note the yellow problem with the V2
V1

V2

Hi Richard !
Here are the results of my comparison of the calibration for cameras V1 and V2 with a non-stock lens.
Dominique
Below for V1 and V2
Unscaled and calibrated white image
An uncalibrated and calibrated image, note the yellow problem with the V2
V1


V2